The dam foundations and abutments should be thoroughly investigated for any possible mechanism of failure. This would involve identification of joints, faults and any other forms of weakness.
A reasonable factor of safety is
- the ratio of shearing resistance to the maximum shearing stress predicted; the lowest value of the ratio in the foundation being the factor of safety of the foundation.